Brand Name : PHiliph Goldway

Model Number : 865492

MOQ : 1pcs

Payment Terms : Full before shipment

Delivery Time : 3-5 working days

Packaging Details : Carton

Product Name : PHiliph Goldway Part No 865492 Multiparameter Module For G60 Modular Patient Monitor

Brand : PHiliph Goldway

Use for : G60 patient monitor

Part No : 865492

Use place : Hospital Devices; Medical Care; ICU;

Warranty : 90 days

Delivery Method : DHL,UPS ,Fedex ,etc

Payment method : T/T ,Paypal ,western union

Contact Now

PHiliphh Goldway Part No 865492 Multiparameter Module For G60 Modular Patient Monitor

To perform a multi-parameter block connection test:

1. Insert the module into the G60 Modular Patient Monitor module slot or Flexible Modular Server (FMS).

2. Turn on the monitor.

3. Check the module light.

If lit:

On = Module is properly connected.

Not lit = Module is not connected properly.

(See the yellow rectangle in the picture below)

4. Press the main menu button and check that the display shows the main menu. (See the picture in the green rectangle below.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Product Name

PHiliphh part no 865492 Multiparameter module for G60 Modular Patient Monitor

Brand PHiliphh Goldway
Part No 865492
Use for G60 patient monitor
Use place Hospital Devices; Medical Care; ICU;
Warranty 90 days
Delivery Time 3-5 working days

In addition to the basic parameters, the multi-parameter module (MPM) has optional parameters: IBP1/IBP2 and 12 lead ECG. The following disassembly procedure applies to both MPMs.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Note :For the multi-parameter module with 12 lead ECG function, a symbole ( PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor) will be printed on the left conner of the multi-parameter module.

Remove the Rear Case

  • Use a utility knife or flat-blade screwdriver to remove the two white plastic nuts on the back

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the two M3X8 screws and washers.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Use the modular rivet wrench to remove the two rivets

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Carefully invert the MPM on a soft surface. Use a flat-blade screwdriver to pry off one end of the module rail

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Insert a second flat-blade screwdriver into the slot on the bottom

of the module rail to release the rail latch as shown.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Slide the module rails in the direction shown in the figure and remove the rails.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Repeat steps 4 through 6 above to remove the second module rail. Remove the two M3x4 screws shown

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the rear case.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Separate Main Frame and Front Panel Assembly

  • Remove the cable and two M3x6 screws from the right side of the front panel

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the two M3X6 screws on the left side of the front panel.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Carefully remove the main body and screen assembly

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Disconnect the SpO2 connector cable, the NIBP / TEMP connector cable (on the front panel), and the NIBP connector tube.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the main body and front panel

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Remove the ECG Board

  • Remove the four M3X6 screws

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Gently pull up the ECG board and remove the NIBP/TEMP connector cable (to ECG board).

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the ECG board.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Remove the SpO2 Board

  • Remove the SpO2 connector cable

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the two white plastic M3X6 screws.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Gently pull up the SpO2 board and remove it. Note the orientation of the board using the circled connector shown

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

If you're interested in PHiliphh Goldway Part No 865492 Multiparameter Module For G60 Modular Patient Monitor ,feel free to contact us .Thank you .


Product Tags:

865492 Multiparameter Module

      

PHiliph Goldway Multiparameter Module

      
Quality PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor for sale

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)