Sign In | Join Free | My tjskl.org.cn
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Defibrillator Machine Parts >

C BeneHeart D6 Defibrillator High Voltage Board 0651-20-76727 Mindray Parts Defibrillator D6 Parts

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

C BeneHeart D6 Defibrillator High Voltage Board 0651-20-76727 Mindray Parts Defibrillator D6 Parts

Brand Name : Mindray

Model Number : 0651-20-76727

MOQ : 1

Payment Terms : T/T(wire transfer), Western Union, Paypal

Delivery Time : 5-8 Work Days

BRAND : Mindray

PRODUCT NAME : Defibrillator High Voltage Board

WARRANTY : 90 Days

CONDITION : In Good Working Order

MATERIAL : Metal

COLOR : Green

MOQ : One Piece

IN STOCK : Yes

MODEL : 0651-20-76727

PAYMENT TERMS : T/T(wire transfer), Western Union, Paypal

ADVANTAGE : Original

TYPE : Defibrillator Parts

FUNCTIONALITY : Good

SERVE : Direct sales, Exchanges, Repairs

Contact Now

Mindray BeneHeart D6 Defibrillator High Voltage Board 0651-20-76727

Brief Introduction

Mindray BeneHeart D6 Defibrillator High Voltage Board 0651-20-76727 is a board that converts the DC low voltage inside the defibrillator machine into AC high voltage. The working principle of the high-voltage board is to convert low DC voltage into high AC voltage.

Feature

The high-voltage board in the defibrillator is a very important internal part of the defibrillator. It is mainly an electrode plate used to deliver defibrillation current to the human body for defibrillation. Defibrillators have two different working modes. There are two electrodes on the defibrillator. One-way wave electric defibrillation can only emit current once. The time for the current to flow through the body is determined by the resistance of the body. It is a one-way current, so defibrillation is It requires a large amount of energy (360J). Bidirectional wave defibrillation can also send out a reverse current after sending out a current, and can control the time of current flow. The current flows through the body twice, so defibrillation requires The energy is small (150J-200J).

The voltage of the defibrillator is converted from the high-voltage plate to convert the DC low voltage into a pulse high voltage. After the high voltage is rectified, it charges the energy storage capacitor C and stores a certain amount of energy in the capacitor. During treatment, the high-voltage plate is controlled to release the energy stored in the capacitor C.

The position of placing the electrode plate, the front end position: A-below the clavicle on the right edge of the sternum, B-on the mid-clavicular line in the center of the electrode plate on the left side of the nipple. Anteroposterior view: A-right subclavian anterior wall, B-left subscapular posterior wall. Posterior apical position: A-apex of the heart, B-behind the right scapular angle.

Causes of damage to the high-voltage board of the defibrillator:

Left for a long time If the high-voltage plate of the defibrillator has not been used for a long time, it may lead to poor contact of the electrode plate and poor current transmission.
Oxidation Long-term storage and high-temperature environment will cause the metal electrodes of the high-voltage board to be oxidized, performance degradation, poor current transmission, high-voltage board failure, etc.
Damage During use, the high-voltage board may be damaged if it is hit, bent, scratched, or the cable connection is loosened.

Repair:

1. Cleaning and Adjustment:

If the high-voltage board of the defibrillator has poor contact or poor current transmission, it can be solved by cleaning and adjusting the high-voltage board. (Be careful to use appropriate cleaning agents to avoid secondary damage.)

2. Replace the high voltage board:

If the damage is serious, the high-voltage board needs to be replaced with a new one in time to avoid damage to other components. (It is recommended to use original accessories or compatible products)

3. Regularly maintain the high-voltage board:

The maintenance of the defibrillator is very important. In order to reduce damage to the parts within the instrument, the defibrillator needs to be maintained regularly and damaged parts replaced in a timely manner to maintain the normal use of the defibrillator.

The high-voltage board of the defibrillator is subject to a lot of damage, such as long-term placement, oxidation, impact, scratches, etc. When the high-voltage board fails, clean, adjust, replace, maintain the high-voltage board, etc. according to the situation. Strengthening the maintenance of defibrillators can effectively reduce damage to defibrillator parts.

Product Details Picture

C BeneHeart D6 Defibrillator High Voltage Board 0651-20-76727 Mindray Parts Defibrillator D6 Parts

C BeneHeart D6 Defibrillator High Voltage Board 0651-20-76727 Mindray Parts Defibrillator D6 Parts

Thank you for taking the time to pay attention to our Mindray BeneHeart D6 Defibrillator High Voltage Board 0651-20-76727 product.


Product Tags:

0651-20-76727 Defibrillator High Voltage Board

      

Mindray Parts Defibrillator High Voltage Board

      

D6 Defibrillator High Voltage Board

      
Quality C BeneHeart D6 Defibrillator High Voltage Board 0651-20-76727 Mindray Parts Defibrillator D6 Parts for sale

C BeneHeart D6 Defibrillator High Voltage Board 0651-20-76727 Mindray Parts Defibrillator D6 Parts Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)